SET-2310 Line Fault Module

2 fault channel multiplex 16 differential / 32 single-ended channels

The main function of the plugin SET-2310 Line Fault Daughter Module is to multiplex test signals on the fault buses. On any SET approved SLSC Card with a plugin module slot, the Line Fault Daughter Module can be easily mounted. With 32 single-ended or 16 differential channels, the SET-2310 provides fault connection capabilities in a small form factor. The fault bus of the Daughter Module directs to the base cards connector to connect any fault device. It is possible to connect two fault signals to the two channel fault bus.

 

Category:

Absolut Maximum Ratings

ConditionValueComment
Relative Humidity5% to 95%Non-condensing
Temperature0° C to 85° C
Storage-40° C to 85° C
Max. Input VoltageAny Pin60 Vdc
Min. Input VoltageAny Pin-60 Vdc
Max. Switching PowerDC, Resistive load60 W
Max. Current Rating (Channel Relais)1.5 A
Max. Current Rating (BUS Relais)8 A

 

Technical Data

ConditionValue
Update Time10 ms
Max Initial Contact ResistanceX1 -> X2300 mOhm
Expected Electrical Lifetime1 A, 30 Vdc resistiveMin 105 operations
Expected Electrical Lifetime1,5 A, 30 Vdc resistiveMin 104 operations

 

Physical Characteristics

ConditionValueComment
Module dimensions10 mm x 52 mm x 235 mm (H x W x D)Standard Module size
Connector to Front2×20 pin female socket terminal strip
Connector to Back2×20 pin terminal strip

 

Environmental

ConditionValue
Operating HumidityRelative,
non-condensing
10% to 90%
Storage HumidityRelative,
non-condensing
5% to 95%
Operating TemperatureForced-air cooling from chassis0° C to 40° C
Storage Temperature-40° C to 85° C
Maximum Altitude2000 m

Downloads

Manual SET-2310 Instrument Module
Manual SET-2310 (pdf, 379KB)