SET-1210

Resistor Simulation Card

Powerful solution for applications requiring simulation of resistive sensors

Overview SLSC Cards
Resistor Simulation Karte

SET 1210 – Resistor Simulation Card

The SET-1210 Resistor Simulation Card provides a powerful solution for applications requiring simulation of resistive sensors.
Our SET-1210 Resistor Simulation Card covers two ranges of values that meet the needs of most functional test systems.

It is designed to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.

Each channel of the Card is able to simulate the common short circuit and open circuit conditions that can be experienced in a system due to faulty wiring or sensors.

Request Article

SET-1210

SKU:
94823

  • 16 channels
  • Very High Accuracy and Stability
  • Bipolar resistor emulation
  • Fully Programmable with a Choice of Resistance Ranges
  • Low Thermo-Electric EMF
  • Simple Verification with an External DMM
  • Suitable for Sensor Emulation Applications
  • Fully Programmable using Resistance Calls to the Driver
  • Supported by National Instruments SLSC Chassis
  • Configurable in small discrete steps, tunes stepless
  • Short and open circuit simulation

  • Enables DUT characterization required in parametric testing
  • RTD and Strain Gauge Simulator
  • HiL Testing
  • Industrial sensors and actuators simulation
  • Simulation of the internal resistance of i.e. lambda sensors
  • Engine temperature sensors simulation

Absolute Maximum Ratings

ConditionValue
Relative HumidityNon-condensing5% – 95%
Temperature0 °C – 85 °C
Storage -40 °C – 100 °C
Max Input VoltageAny Pin 60 V Transient 65 V
Min Input VoltageAny Pin -60 V Transient -65 V

Signal Card

R Range V Range I Range
Range 110 Ω – 10 kΩ±0 – 25 V±0 – 10 mA
Range 21 kΩ – 1 MΩ±0 – 25 V±0 – 10 mA

Absolute Maximum Ratings

ConditionValue
Channels16
Resistance10 Ω to 10 kΩ
Current ±0 – 10 mA
Voltage±0 – 25 V, Possible higher
Overall Accuracy±0.0005 A – ±10 mA 15°C -50°C< 30%
Overall Accuracy ±0.0001 A – ±10 mA 15°C -50°C< 15%
Overall Accuracy±0.0005A – ±10 mA 50 Ω to 10kΩ 15 °C – 50 °C< 6%, PT100 Range -125°C to max
Overall Accuracy±0.0001 A – ±10 mA 50 Ω to 10 kΩ 15 °C – 50 °C< 3%, PT100 Range -125 °C to max
Resolution0.2 Ω / LSB, possible lower
Settling Time< 10 ms, possible lower

Absolute Maximum Ratings

ConditionValue
Resistance 1 kΩ to 1 MΩ
Current ±0 – 10 mA
Voltage ±0 – 25 V, possible higher
Overall Accuracy1 kΩ – 10 Ω 100 µA – 10 mA< 6%, possible < 5%
Overall Accuracy 10 kΩ – 1 MΩ 1 mA – 10 mA< 0,2%, possible 0,1%
Overall Accuracy 1 kΩ – 10 kΩ 1 mA – 10 mA< 1%
Overall Accuracy 100 kΩ – 1 MΩ 10 µA – 10 mA< 2%
Resolution20 Ω / LSB, possible lower
Settling Time< 10 ms, possible lower

SET-1210-Technical-Description Download Documenation