SET-1210 Resistor Simulation Card2018-11-12T10:27:28+00:00

SET-1210
Resistor Simulation Card

Powerful solution for applications requiring simulation of resistive sensors

The SET-1210 Resistor Simulation Card provides a powerful solution for applications requiring simulation of resistive sensors.

The SET-1210 Card covers two ranges of values that meet the needs of most functional test systems.

It is designed to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.

Each channel of the SET-1210 Resistor Simulation Card is able to simulate the common short circuit and open circuit conditions that can be experienced in a system due to faulty wiring or sensors.

Features

  • 16 channels
  • Very High Accuracy and Stability
  • Bipolar resistor emulation
  • Fully Programmable with a Choice of Resistance Ranges
  • Low Thermo-Electric EMF
  • Simple Verification with an External DMM
  • Suitable for Sensor Emulation Applications
  • Fully Programmable using Resistance Calls to the Driver
  • Supported by National Instruments SLSC Chassis
  • Configurable in small discrete steps, tunes stepless
  • Short and open circuit simulation

Absolute Maximum Ratings

ConditionValue
Relative HumidityNon-condensing5% – 95%
Temperature0 °C – 85 °C
Storage-40 °C – 100 °C
Max Input VoltageAny Pin60 V
Transient 65 V
Min Input VoltageAny Pin-60 V
Transient -65 V

Signal Card

R RangeV RangeI Range
Range 110 Ω – 10 kΩ±0 – 25 V±0 – 10 mA
Range 21 kΩ – 1 MΩ±0 – 25 V±0 – 10 mA

Absolute Maximum Ratings

ConditionValue
Channels16
Resistance10 Ω to 10 kΩ
Current±0 – 10 mA
Voltage±0 – 25 V,
Possible higher
Overall Accuracy±0.0005 A – ±10 mA
15°C -50°C
< 30%
Overall Accuracy±0.0001 A – ±10 mA
15°C -50°C
< 15%
Overall Accuracy±0.0005A – ±10 mA 50 Ω to 10kΩ
15 °C – 50 °C
< 6%,
PT100 Range -125°C to max
Overall Accuracy±0.0001 A – ±10 mA 50 Ω to 10 kΩ
15 °C – 50 °C
< 3%,
PT100 Range -125 °C to max
Resolution0.2 Ω / LSB, possible lower
Settling Time< 10 ms, possible lower

Absolute Maximum Ratings

ConditionValue
Resistance1 kΩ to 1 MΩ
Current±0 – 10 mA
Voltage±0 – 25 V, possible higher
Overall Accuracy1 kΩ – 10 Ω
100 µA – 10 mA
< 6%, possible < 5%
Overall Accuracy10 kΩ – 1 MΩ
1 mA – 10 mA
< 0,2%, possible 0,1%
Overall Accuracy1 kΩ – 10 kΩ
1 mA – 10 mA
< 1%
Overall Accuracy100 kΩ – 1 MΩ
10 µA – 10 mA
< 2%
Resolution20 Ω / LSB, possible lower
Settling Time< 10 ms, possible lower

Applications

  • Enables DUT characterization required in parametric testing
  • RTD and Strain Gauge Simulator
  • HIL Testing
  • Simulation industrial sensors and actuators
  • Simulation of the internal resistance of i.e. lambda sensors
  • Simulation of engine temperature sensors

Contact

You have questions? Our SLSC support team is always happy to answer your questions.
Just write an E-Mail to support-slsc@smart-e-tech.de or call +49 7522 916 87 600.