The SET-1215 RTD simulation card is a high precision 16 channel resistance temperature detector simulator.

The simulation range is from 90 Ohm to 410 Ohm and 900 Ohm to 4100 Ohm with an accuracy up to 1°C.

It contains 16 galvanic isolated channels which can be connected in 2-terminal sensing and 4-terminal sensing.
Each channel of the SET-1215 card is able to simulate the common short circuit and open circuit conditions, which could be experienced in a system due to faulty wiring or sensors.

To maximize customizability, the SET-1215 have two plug-in module slots that can provide features like line fault insertion and instrument connect. Additionally, the SET-1215 RTD Card comes with a high current fault injection bus.

Absolute Maximum Ratings

ConditionValueComment
Max. Input VoltageAny Pin to Chassis GND60 VDCTransient 65V,
Limited by connector
Min. Input VoltageAny Pin to Chassis GND-60 VDC
Max. Input VoltageBetween CHx_F+ and ChxF-15 V
Min. Input VoltageBetween CHx_F+ and ChxF--0.3 V
Max. Short Circuit Current1.5 A
Max. Simulation Current10 mA
Min. Simulation Current100 µA
Max. Switching PowerDC, Resistive load60 W
Max. Simulation Power400 mW

Technical Data

ConditionValueComment
Max. Simulation VoltageBetween CHx_F+ and ChxF-10 V
Min. Simulation VoltageBetween CHx_F+ and ChxF-0 V
Resistor Value Update Time50 µsSLSC communication delay not included
Simulation ResolutionPT100 configuration0.1 Ω
PT1000 configuration1 Ω
Initial Resistance< 10 M
Expected Electrical Relay Lifetime1A, 30VDC resistiveMin 105 operations
2 A, 30 VDC resistiveMin 104 operations

Physicals Characteristics

ConditionValueComment
Module DimensionsExcluding ejector144.32mm x 30.48mm x 302mm (H x W x D)Standard SLSC card size
Front Panel Connector2x female DB -44 high-density D-Sub with 4-40 UNC screw lockFor mating connectors and cables, contact us
RTI Connector2mm hard metric per IEC 61076-101Any RTI marked

Environmental

ConditionValue
Operating HumidityRelative,
non-condensing
10% – 90%
Storage HumidityRelative,
non-condensing
5% – 95%
Operating TemperatureForced-air cooling from chassis0 °C – 40 °C
Storage Temperature-40 °C – 85 °C
Maximum Altitude2000 m

Downloads

Manual SET-1215 RTD-SIM (PT100/PT1000)
Manual SET-1215 (pdf, 1MB)