SMARTbrick 2400A

4-20mA CURRENT INPUT

For evaluation of current outputs

Overview
SMARTbrick 2400A – 4-20mA CURRENT INPUT

SMARTbrick 2400A – 4-20mA CURRENT INPUT

A single-channel current measuring module with galvanic isolation is used to analyse power outputs. A load resistance of 75 Ohm is used for current analysis. A line break and a short circuit can be stimulated for error stimulations. The error stimulation is specified in connection with the carrier board via CAN bus.

Request Article

SMARTbrick 2400A

SKU:
85279

Channels1
Input Voltage 24 VDC
Input Current 4 mA – 20 mA
Max. permissible total error± 0.1 mA
Max. short circuit current50 mA
Internal resistance in short circuitmax. 3.5 Ω
Load resistance75 Ω ± 5 Ω
Insulation voltagemax. 50 VDC
Insulation Resistance 1 MΩ
ADC Resolution12 Bit

Modulfunctions

Error stimulation „line breakage“ via software
Error stimulation „Short circuit“ via software
Display of error stimuliesvia LED’s